6kw, 9kw, 12kw, 16kw, 19kw a+++ R32 DC Inverter Air to Water Multi Functional Heat Pump

Product Details
Customization: Available
Certification: RoHS, CB, CCC, ISO9001, CE
Working Medium: R32
Still deciding? Get samples of US$ 2500/Piece
Request Sample

360° Virtual Tour

Diamond Member Since 2022

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
54
Year of Establishment
2009-11-16
  • 6kw, 9kw, 12kw, 16kw, 19kw a+++ R32 DC Inverter Air to Water Multi Functional Heat Pump
  • 6kw, 9kw, 12kw, 16kw, 19kw a+++ R32 DC Inverter Air to Water Multi Functional Heat Pump
  • 6kw, 9kw, 12kw, 16kw, 19kw a+++ R32 DC Inverter Air to Water Multi Functional Heat Pump
  • 6kw, 9kw, 12kw, 16kw, 19kw a+++ R32 DC Inverter Air to Water Multi Functional Heat Pump
  • 6kw, 9kw, 12kw, 16kw, 19kw a+++ R32 DC Inverter Air to Water Multi Functional Heat Pump
Find Similar Products

Basic Info.

Model NO.
AH16DCR-R32
Cop
5.98
Noise
46 ~ 50 dB (a)
Compressor
Mitsubishi
Compressor Type
Twin Rotary
Max.Water Temper
60 Degrees Celsius
Running Tempera
-25 ~ 43 Degrees Celsius
Transport Package
Carton
Specification
6kw ~ 19kw
Trademark
Palm
Origin
Guangzhou, China
HS Code
8418612090

Product Description

Nowadays, due to the constant rise in oil and gas prices, there is an increasing need for energy efficient products that provide greater savings to users. Heat pumps offer a very efficient and cost-effective way to heat homes, replacing
boilers that use gas or other fossil fuels.
Most of homes and hotels use conventional and energy-inefficient systems such as gas boilers or furnace  in order to produce room heating, and domestic hot water. 
Main advantages of using a heat pump compared to a boiler:
• Energy upgrading of buildings
• Energy efficiency and operating cost reductions up to 70%
• Return on investment approximately within 3 years

Main advantages of using a heat pump compared to a central solar field:
• Faster return of investment
• Less space required
• Less need for maintenance
• Smaller volume of hot water storage tanks and hence less space for boiler rooms
Solustions by Palm DC Inverter Heat Pump

• Specifically designed for heating applications Nominal capacity from 6kW to 19kW
• Energy Label A+++
• Maximum water temperature 70°C
• Guaranteed operation without the performance reduction nor the temperature of the produced water, for ambient temperatures up to 53°C
• Choice of anti-corrosion protection
• External heat source control
• Master-slave units factory-installed parallel operation
• Pro Dialog Plus controller with liquid crystal display
• Communication with MODBUS systems


Features 
6kw, 9kw, 12kw, 16kw, 19kw a+++ R32 DC Inverter Air to Water Multi Functional Heat Pump

6kw, 9kw, 12kw, 16kw, 19kw a+++ R32 DC Inverter Air to Water Multi Functional Heat Pump

6kw, 9kw, 12kw, 16kw, 19kw a+++ R32 DC Inverter Air to Water Multi Functional Heat Pump
Application

6kw, 9kw, 12kw, 16kw, 19kw a+++ R32 DC Inverter Air to Water Multi Functional Heat Pump
Application with solar for room heating and DHW

6kw, 9kw, 12kw, 16kw, 19kw a+++ R32 DC Inverter Air to Water Multi Functional Heat Pump

High quality components 
6kw, 9kw, 12kw, 16kw, 19kw a+++ R32 DC Inverter Air to Water Multi Functional Heat Pump
Technical Data 
Models   Air temp/outlet water temp AH6DCR-R32 COP AH9DCR-R32 COP AH12DCR-R32 COP AH16DCR-R32 COP AH19SDCR-R32 COP
Heating capacity/Power input (KW) at A20/W35°C  8.44/1.41 5.99 12.1/2.02 5.99 16.32/2.77 5.89 21.88/3.66 5.98 25.4/4.5 5.64
at A7/W35°C  6.21/1.26 4.93 8.9/1.81 4.92 12/2.5 4.8 16.3/3.34 4.88 18.7/4.06 4.61
at A7/W45°C  5.91/1.48 3.99 8.46/2.12 3.99 11.29/3.08 3.67 15.31/3.88 3.95 17.78/4.75 3.74
at A2/W35°C  5.56/1.22 4.56 7.97/1.76 4.53 10.8/2.44 4.43 14.49/3.23 4.49 16.8/3.97 4.23
at A2/W45°C  5.32/1.45 3.67 7.61/2.07 3.68 10.16/3.01 3.38 13.78/3.8 3.63 16/4.65 3.44
Cooling Capacity/Power input(KW) at A35/ W18ºC 6.35/1.6 3.97 8.1/2.08 3.89 11/3.12 3.53 15.6/4.3 3.63 16.6/4.5 3.69
at A35/W7ºC 4.9/1.65 2.97 5.9/2 2.95 8.1/2.83 2.86 11.4/4 2.85 12/4.2 2.86
Compressor   Mitsubishi   Mitsubishi   Mitsubishi   Mitsubishi   Mitsubishi  
Max.currentt                           (A) 13   13   19   25   9  
Electric supply 230V/50-60Hz 230V/1Phase or 400V/3Phase 50~60HZ
Max.water temperature            ( oC) 60
Running temperature range      (oC) -25 ~ 43
Refrigerant circuit Refrigerant R32
DC Inverter compressor(s) Twin Rotary
Heat exchange Copper and Hydrauphilic Aluminum Fin
Air flow     (m3/h) 2100   2400   2900   5600   5600  
Water circuit Heat exchanger Plate heat exchanger      
In/Out pipe DN25(1'')   DN25(1'')   DN32
Water flow  (m3/h) 0.8   ≥1.2   1.8   ≥2.3   ≥2.3  
permitted pressure ≤0.8MPa
Unit dimensions   WxHxD   (mm) 1115*710*425   1115*710*425   1115*960*425   1115*1280*425   1115*1280*425  
Pacage dimensions   WxHxD   (mm) 1160*860*520   1160*860*520   1160*1110*520   1160*1440*520   1160*1440*520  
Net weight                               (Kg) 90   90   105   140   140  
Gross weight                            (Kg) 102   102   115   150   150  
Noise level                             (dB(A)) 46   46   50   52   52  
Loading quantity for 20'/40' 44/88   44/88   44/88   22/44   22/44  
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier