80kw~250kw Ciepł a Heat Pump

Product Details
Customization: Available
Certification: SASO, RoHS, CB, CCC, ISO9001, CE
Working Medium: R410A
Still deciding? Get samples of US$ 2500/Piece
Request Sample

360° Virtual Tour

Diamond Member Since 2022

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
54
Year of Establishment
2009-11-16
  • 80kw~250kw Ciepł a Heat Pump
  • 80kw~250kw Ciepł a Heat Pump
  • 80kw~250kw Ciepł a Heat Pump
Find Similar Products

Basic Info.

Model NO.
KRS-300E/SN2-M
Cop
4.17
Noise
58 dB
Transport Package
Carton with Crate
Specification
30KW
Trademark
Kolant
Origin
Guangzhou, China
HS Code
8418612090

Product Description

Nowadays, due to the constant rise in oil prices, there is an increasing need for energy efficient products that provide greater savings to users. The hotel industry is among the most energy-intensive sectors of the economy, meaning soaring costs for operating the facilities. Most of the hotels use conventional and energy-inefficient systems such as conventional boilers in order to produce domestic hot water. The need to find more economical energy upgrading solutions for existing installations is imperative. The attention of interested parties is mostly directed towards the use of heat pumps or solar energy.
These and many advantages prove that the use of a heat pump is the best solution for the needs of a hotel.

Main advantages of using a heat pump compared to a boiler:
• Energy upgrading of buildings
• Energy efficiency and operating cost reductions up to 70%
• Return on investment approximately within 3 years

Main advantages of using a heat pump compared to a central solar field:
• Faster return of investment
• Less space required
• Less need for maintenance
• Smaller volume of hot water storage tanks and hence less space for boiler rooms

Solutions by Kolant for air to water production

• Specifically designed for heating applications Nominal capacity from 10kW to 250kW
• Maximum water temperature 65°
C
• Guaranteed operation without the performance reduction nor the temperature of the produced water, for ambient temperatures up to 43°C
• Choice of anti-corrosion protection
• External heat source control
• Master-slave units factory-installed parallel operation
• Newly-designed Flying Bird IV fans with very low noise level
• Pro Dialog Plus controller with liquid crystal display
• Communication with existing MODBUS systems

80kw~250kw Ciepł a Heat Pump
Powerful Heat Pumps for Commercial Hot Water
Energy consumption of hot water accounts for a considerable percentage in commercial buildings. According to some investigation, this percentage can even be as high as 40% in some hotels, nursing homes, hospitals etc. Heat pumps, however, generate hot water mostly with renewable energy are especially suitable for commercial hot water project. Using KOLANT heat pumps as the heating devices or replacing those existed boilers in commercial buildings makes great benefits in economic and environmental prospects. With large capacity range from 10kW to 250kW, KOLANT commercial heat pumps provides various choices for users to get the most cost-effective solution for hot water projects.

80kw~250kw Ciepł a Heat Pump

80kw~250kw Ciepł a Heat Pump

80kw~250kw Ciepł a Heat Pump


80kw~250kw Ciepł a Heat Pump



80kw~250kw Ciepł a Heat Pump
Model KRS-800E/SN1-V KRS-1000E/SN1-V KRS-1250E/SN1-V KRS-1600E/SN1-V KRS-2000E/SN1-V KRS-2500E/SN1-V
Power supply Ph-V-Hz 380V/3PH/50HZ 380V/3PH/50HZ 380V/3PH/50HZ 380V/3PH/50HZ 380V/3PH/50HZ 380V/3PH/50HZ
Working temp ºC -15ºC~43ºC -15ºC~43ºC -15ºC~43ºC -15ºC~43ºC -15ºC~43ºC -15ºC~43ºC
Max. outlet Water temp. ºC 60ºC 60ºC 60ºC 60ºC 60ºC 60ºC
Water Heating (A20/W55) Capacity KW 80 100 125 160 200 250
Hot water yield L/h 1720 2150 2687 3439 4299 5374
Input KW 19.3 24 30.3 38.6 48 60.6
Rated current A 31.79 39.53 49.90 63.57 79.05 99.80
Hot water yield m3/h            
Max. input consumption                   KW 28.95 36 45.45 57.9 72 90.9
Max. input current A 47.68 59.29 74.85 95.36 118.58 149.70
Wire controller Type   Intelligent   &  LCD Intelligent   &  LCD Intelligent   &  LCD Intelligent   &  LCD Intelligent   &  LCD Intelligent   &  LCD
The length of wires m 12 12 12 12 12 12
set Temp. ºC 25~60 25~60 25~60 25~60 25~60 25~60
Water system materials of water pipe   copper  copper  copper  copper  copper  copper 
water flow m3/h 17.2 21.5 26.9 34.4 43.0 53.7
Water different pressure Kpa 60 60 60 70 70 70
Diameter,water inlet pipe mm DN50 DN50 DN50 DN65 DN65 DN65
Diameter,water outlet pipe mm DN50 DN50 DN50 DN65 DN65 DN65
Design pressure  Mpa 2.8/0.02 2.8/0.02 2.8/0.02 2.8/0.02 2.8/0.02 2.8/0.02
Outdoor noise level  (1 meter) dB(A) 70 70 70 72 72 72
Outdoor unit Dimension(L*W*H) mm 2000/980/1960 mm 2000/980/1960 mm 2000/980/2062 mm 2000*2160*2335 2000*2160*2335 2000*2160*2335
Packing(L*W*H) mm 2130/1100/2150 mm 2130/1100/2150 mm 2130/1100/2260 mm 2090*2290*2460 2090*2290*2460 2090*2290*2460
NG/WG kg            
Testing condition: ambient Dry/Wet Bulb Temp.: 20ºC/15ºC; Water Inlet/Outlet Temp.: 15ºC/55ºC.

 