Customization: | Available |
---|---|
Certification: | ISO9001, CE, En14825 |
Working Medium: | R32 |
Still deciding? Get samples of US$ 1500/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
to replace Traditional boiler ,oil burner and air conditioner for domestic/commercial usage
Strong Heating in Super Cold Air Temp.
Super cold ambient temp heating technology use the EVI compressor high efficent cooler and EEV to form high efficient jet system to increase compressor suction capacity at super low air temp and increase the whole system heating efficiency and performance. This technology make heat pump to keep normal heating without electric heater assistant.
Kolant EVI heat pump heating capacity and COP concession during cold air temp is very small. Our full range of EVI Inverter het pumps get the EN14825 testing report from TUV for European A+++ energy class. Our heat pump is compliant with European EN813 standard.
There is no doubt that air source heat pumps can make great economic and environmental benefts if they are properly used. However, as a matter of fact, most air source heat pumps work with very poor eficiency or even can not work when the environment temperature is lower than -10ºC. The EVl (enhanced vapor injection) heating technology is an innovation in the compressor and the refrigerant circulation. By this technology the permitted operating range of a heat pump is extended to a much lower air temperature region, and the heating performance under low environment temperature is greatly improved.
Reliable running under environment temperature to -30C air temp Getting much higher water temperature during low environment temperature Heating capacity up to 40% higher than normal heat pumps COP 10%-20% higher during low environment temperature.
By the innovative technologies,Kolant heat pump is able to use Wifi cloud control and enable authorized user to control KOLANT heat pumps anytime, anywhere just via a mobile phone. Just imagine that you turn on your heat pump on your way home, then you can enjoy the comfortable environment created by KOLANT heat pumps as soon as you arrive at home. The Wifi control will also send error code to provide much help on aftersales service.
Modbus Protocol available
Except wired controller and central controller, KOLANT heat pumps are specially designed to provide modbus protocol inside, this means your heat pumps can be controlled by your computer or your own built automatic control system if it is necessary. This is specially useful for the central control or customized control system.
All the important components of KOLANT EVl heat pumps are from world-famous brands to make sure the high reliability and durability within its permitted operating range.
Kolant EVI heat pump specification:
Models | Air temp/outlet water temp |
RJ85/N8-BPEEVI | COP | RJ-110/N8-BPE | COP | RJ-150/SN8-BPEEVI | COP | RJ-180/SN8-BPEEVI | COP | RJ-230/SN8-BPEEVI | COP |
Heating capacity/Power input (KW) | at A20/W35°C | 10.6/1.89 | 5.61 | 14.42/2.88 | 5.01 | 21.1/3.89 | 5.42 | 22.8/4.4 | 5.18 | 29.5/6.01 | 4.91 |
at A7/W35°C | 8.6/1.87 | 4.6 | 11.2/2.41 | 4.65 | 14.7/3.31 | 4.44 | 18.8/4.11 | 4.57 | 23.15/5.3 | 4.37 | |
at A7/W45°C | 7.91/2.23 | 3.55 | 10.36/2.45 | 4.23 | 13.5/4.1 | 3.29 | 17.8/5.24 | 3.4 | 22.6/6.11 | 3.7 | |
at A2/W35°C | 7.65/1.81 | 4.23 | 10.3/2.41 | 4.27 | 13.08/3.21 | 4.07 | 16.92/4.31 | 3.93 | 20.29/5.38 | 3.77 | |
at A2/W45°C | 7.04/2.15 | 3.27 | 9.32/2.57 | 3.63 | 12.02/3.97 | 3.03 | 16/5.12 | 3.13 | 18.7/6.4 | 2.92 | |
at A-12/W41°C | 5.9/2.45 | 2.41 | 7.1/2.56 | 2.77 | 10.2/4.35 | 2.34 | 11.6/5.04 | 2.3 | 14.7/5.88 | 2.5 | |
at A-20/W41°C | 5.4/2.56 | 2.11 | 5.9/2.65 | 2.23 | 8.9/4.23 | 2.1 | 10.5/4.97 | 2.11 | 13.7/5.78 | 2.37 | |
Cooling Capacity/Power input(KW) / |
at A35/ W18ºC | 9.2/2.7 | 3.41 | 11/3.3 | 3.33 | 13.9/4.2 | 3.31 | 15.6/4.8 | 3.25 | 20.1/6.2 | 3.24 |
at A35/W7ºC | 7.2/2.73 | 2.64 | 8.6/3.4 | 2.53 | 9.8/3.77 | 2.6 | 10.5/4.2 | 2.5 | 13.5/5.09 | 2.65 | |
Max.current (A) | 18 | 19 | 28 | 14.3 | 18.1 | ||||||
Electric supply / | 230V/50~60HZ | 400V/50~60HZ | 400V/50~60HZ | ||||||||
Max.Outlet water temperature ( oC) | 60 | ||||||||||
Running temperature range (oC) | -30 ~ 43 | ||||||||||
Refrigerant circuit | Refrigerant | R32 | |||||||||
DC Inverter compressor(s) | MITSUBISHI | MITSUBISHI | MITSUBISHI | MITSUBISHI | MITSUBISHI | ||||||
Heat exchange | Copper and Hydrauphilic Aluminum Fin | ||||||||||
Air flow (m3/h) | 2400 | 5800 | 6000 | 7000 | |||||||
Water circuit | Heat exchanger | High efficiency tube in shell heat exchanger | |||||||||
In/Out pipe | DN25(G1") | DN25(G1") | DN25(G1") | DN25(G1") | DN25(G1") | ||||||
Water flow (m3/h) | ≥1.5 | ≥1.8 | ≥2.5 | ≥3 | ≥3.9 | ||||||
permitted pressure | ≤0.8MPa | ||||||||||
Unit dimensions WxHxD (mm) | 960*820*380 | 960*820*380 | 960*1270*380 | 960*1270*380 | 1030*1340*390 | ||||||
Pacage dimensions WxHxD (mm) | 1040*940*502 | 1040*940*502 | 1040*1390*502 | 1040*1390*502 | 1115*1510*510 | ||||||
Net weight (Kg) | 68 | 68 | 108 | 108 | 128 | ||||||
Gross weight (Kg) | 85 | 85 | 125 | 125 | 145 | ||||||
Noise level (dB(A)) | 56 | 56 | C59 | 59 | 60 | ||||||
Container loading quantity(20'/40') | 44/88 | 22/44 | 22/44 | 22/44 |